Freight date |
|
|
to grant authorization |
RCM Mark |
|
CESymbol(Refer to the applicable standards) |
According to EU-EMVguiding principle |
|
Certification issuing department |
UL E322346 |
|
Material remarks |
Compliant with RoHS |
|
Measure variables |
Relative pressure |
|
Measurement method |
Piezoresistive pressure sensor |
|
Pressure measurement range, initial value |
-1 bar |
|
Pressure measurement range, final value |
1 bar |
|
Overload range |
5 bar |
|
Working medium |
Compressed air complies with ISO8573-1:2010 [7:4:4] |
|
Explanation on Work and Lead Medium |
Lubricated compressed air can be used |
|
Medium temperature |
0 50 °C |
|
ambient temperature |
0 50 °C |
|
Accuracy, FS |
1.5 %FS |
|
Repetitive accuracy zero point, in ±% FSexpress |
0.3 %FS |
|
Temperature coefficient, measured in ±% FS/Kexpress |
0.05 %FS/K |
|
Switch output |
2 x PNPor2 x NPNConvertible |
|
Switch function |
window comparator |
|
Switching component functions |
N/CorN/Ocontact,Switchable |
|
Maximum output current |
100 mA |
|
Short circuit strength |
yes |
|
Working voltage range DC |
15 ... 30 V |
|
Polarity fault-tolerant protection |
For all electrical interfaces |
|
Electrical connection |
Plug |
|
Electrical interface 1,Interface type |
Plug |
|
Electrical interface 1,Interface technology |
Interface form L1J |
|
Electrical interface 1,Pin Pin/The number of lines |
4 |
|
Installation type |
Front panel installation |
|
Assembly position |
arbitrarily |
|
Pneumatic connection |
Male thread R1/8 |
|
Product weight |
46 g |
|
Material information, shell |
PA-strengthen |
|
Display type |
Luminous LCD |
|
Units that can be displayed |
MPa |
|
Set options |
Teach-In |
|
Prevent misoperation |
PIN-Code |
|
Range of critical values |
0 100 % |
|
Delay setting range |
0 90 % |
|
Protection level |
IP40 |
|
Corrosion resistance grade CRC |
2 –Moderate corrosion impact |